Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/26
Title: Poly-nile Blue Based Electrochemical Sensor for Catechol and Hydroquinone
Authors: Teradale, Amit B.
Lamani, Shekappa D.
Pattan S., Ganesh
Bahaddurghatta E
Kumara Swamy
Das, Swastika N.
Keywords: Catechol, Hydroquinone, Poly-Nile Blue Modified Glassy Carbon Electrode, Voltammetry
Issue Date: 2019
Series/Report no.: 1176-1190;
Abstract: An electrochemical sensor was developed for the electroanalysis of catechol (CC) and hydroquinone (HQ) using poly-nile blue (NB) modified glassy carbon electrode (MGCE) i.e., poly-NB/MGCE. The fabricated electrode showed an excellent electrocatalytic activity towards the electrooxidation of CC and HQ in 0.2 M phosphate buffer solution (PBS) of pH 7.4 by using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The effect of scan rate suggests the adsorption and diffusion controlled electrode process for CC and HQ respectively. The limit of detection of CC and HQ was found to be 53.2 nM and 31.5 nM by CV techniques. Overall, the sensitivity, selectivity, stability, linearity and reproducibility were obtained at the poly-NB/MGCE.
URI: http://hdl.handle.net/123456789/26
Appears in Collections:F P

Files in This Item:
File Description SizeFormat 
Poly-nile blue based electrochemical sensor for catechol and hydroquinone.pdf1.27 MBAdobe PDFView/Open